| Parametras | Vertė |
|---|---|
| 599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| Elektromagnetinis suderinamumas | Conformance with EMC Directive 2014/30/EU |
| MTBF | 284 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Pastaba | Please follow the special installation instructions in the documentation! |
| Gylis | 114.5 mm |
| Įvestis | ± 2 kV (Test Level 3) |
| Plotis | 22.5 mm |
| Ūgis | 99 mm |
| Signalas | Ethernet |
| Įtampa | 10 V |
| Aukštis | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Komentarai | Criterion B |
| Drėgmė | A |
| Korpusas | Required protection according to the Rules shall be provided upon installation on board |
| Vibracija | A |
| CCCex pastaba | Use in potentially explosive areas is not permitted in China. |
| Bangos ilgis | 1300 nm |
| sertifikatas | CE-compliant |
| A kriterijus | Normal operating behavior within the specified limits. |
| B kriterijus | Temporary impairment to operational behavior that is corrected by the device itself. |
| Pluoštų tipai | 50/125 µm |
| Signaliniai šviesos diodai | Activity, link status, 10/100 Mbps |
| Temperatūra | B |
| Nuoroda per | Link fault pass through |
| Produkto tipas | Media converter |
| Signalo vėlavimas | ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
| Montavimo tipas | DIN rail mounting |
| Identifikavimas | II 3 G Ex nA IIC T4 Gc X |
| Pagrindinės funkcijos | Store-and-forward media converter |
| Spalva (korpusas) | green (RAL 6021) |
| Lauko intensyvumas | 10 V/m |
| Dažnių diapazonas | 80 MHz ... 3 GHz (Test Level 3) |
| Kanalų skaičius | 1 |
| Straipsnio peržiūra | 11 |
| Išleidimas į orą | ± 8 kV (Test Level 3) |
| Nuėmimo ilgis | 7.00 mm |
| Prijungimo būdas | Plug-in screw terminal block (COMBICON), redundancy possible |
| Kontaktinis iškrovimas | ± 6 kV (Test Level 3) |
| Priveržimo sukimo momentas | 0.56 Nm ... 0.79 Nm |
| Netiesioginis išleidimas | ± 6 kV |
| Medžiaga (korpusas) | PA 6.6-FR |
| Apsauginė grandinė | Reverse polarity protection |
| Perdavimo greitis | 10/100 Mbps |
| Matmenų brėžinys | |
| Perdavimo ilgis | 100 m (shielded twisted pair) |
| Perdavimo terpė | Single-mode fiberglass |
| Apsaugos laipsnis | IP20 |
| Elektros izoliacija | according to IEEE 802.3 |
| Maitinimo įtampos diapazonas | 18 V DC ... 30 V DC (Screw connection) |
| MDI-/MDI-X perjungimas | Auto-MDI(X) |
| Standartai / reglamentai | EN 61000-4-2 |
| Automatinio derinimo režimai | Auto |
| Nominali maitinimo įtampa | 24 V DC |
| Perdavimo pajėgumas, maksimalus | ≤ -8 dBm ((9/125 µm) dynamic in link mode (average)) |
| Minimalus perdavimo pajėgumas | ≥ -15 dBm ((9/125 µm) dynamic in link mode (average)) |
| Tipinis srovės suvartojimas | 100 mA (24 V DC) |
| Maksimalus imtuvo jautrumas | -7 dBm (dynamic in link mode (average)) |
| Minimalus imtuvo jautrumas | -31 dBm (dynamic in link mode (average)) |
| Aplinkos temperatūra (darbinė) | -40 °C ... 65 °C |
| Leistinas drėgnumas (darbas) | 5 % ... 95 % (non-condensing) |
| Vieno laido / gnybto vieta, lanksti | 0.2 mm² ... 2.5 mm² |
| Vienas laidininkas/gnybtas, standus | 0.2 mm² ... 2.5 mm² |
| Aplinkos temperatūra (sandėliavimo / transportavimo) | -40 °C ... 85 °C |
| Laidininko skerspjūvis, lankstus [AWG] | 24 ... 14 |
| Leistinas drėgnumas (sandėliuojant / transportuojant) | 5 % ... 95 % (non-condensing) |
| Bandymo įtampos duomenų sąsaja / maitinimo šaltinis | 0.5 kVrms(50 Hz, 1 min.) |
| Perdavimo ilgis, įskaitant 3 dB sistemos rezervą | 36 km (F-E 9/125 0.36 dB/km) |
| Maksimali galios disipacija nominaliomis sąlygomis | 2.4 W |
| Be medžiagų, kurios galėtų pakenkti dangos padengimui | VDMA 24364:2018-05 |