HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
Sandėlyje Karštas produktas

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46 JAV dolerių
326 sandėlyje
Pagrindinės specifikacijos
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Tipas: D7
Testai: DIN VDE 0627/86
Plotis: 21 mm
Tiekėjo informacija
Produktai: 0
Paprastai išsiunčiama per 2–3 darbo dienas
Kokybės garantija
Greitas pristatymas
Techninė pagalba

Techninės specifikacijos

Parametras Vertė
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Tipas D7
Testai DIN VDE 0627/86
Plotis 21 mm
Ūgis 34.8 mm
Ilgis 21 mm
Serija HC-HS
Bendra for HC-D7 housing, axial connection 2.0 mm, Allen key
Paraiška Power
Produkto tipas Contact insert with a fixed no. of positions
Surinkimo pastaba To ensure correct use, installation in housing with IP54 protection or better is required
Nominali srovė 40 A
Straipsnio peržiūra 04
Kontaktinis skersmuo 4 mm
Kontaktinė medžiaga Copper alloy
Šešiakampis lizdas SW2,0
Kontaktinis numeris 1 - 2
Priveržimo sukimo momentas 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Ryšio profilis 2+PE
Taršos laipsnis 3
Matmenų brėžinys
Pozicijų skaičius 2
Nominali viršįtampis 6 kV
Viršįtampio kategorija III
Ryšio technologija Axial screw connection
Kontaktinės medžiagos tipas turned
Maitinimo kontaktų skaičius 2
Nominali įtampa (III/3) 400 V
Laidininko skerspjūvis 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Kontaktinio nešiklio medžiaga PC
Kontaktinio paviršiaus medžiaga Ag
Įdėjimo / ištraukimo ciklai ≥ 500
Jungties skerspjūvis AWG 10 ... 8
Aplinkos temperatūra (darbinė) -40 °C ... 125 °C (including heating up of contacts)
Prijungimas pagal standartą IEC / EN
Konstrukcijos ir bandymų taisyklės DIN VDE 0627/86
Degumo įvertinimas pagal UL 94 V0
Atskiro laido izoliacijos ilgis 8 mm +1 mm

Produkto aprašymas

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Pagrindinės savybės
  • Pramoninės klasės kokybė
  • Atitinka RoHS reikalavimus
  • CE sertifikuotas
  • 1 metų garantija

Produkto dokumentai

Duomenų lapas

Techninės specifikacijos ir našumo duomenys

Vartotojo vadovas

Montavimo ir naudojimo vadovas