| Parametras | Vertė |
|---|---|
| GTIN | 4046356095372 |
| Pastaba | Made to Order (non-returnable) |
| Užsakymo raktas | 1637168 |
| Katalogo puslapis | Page 551 (C-4-2015) |
| Pakavimo vienetas | 1 pc |
| Kilmės šalis | DE (Germany) |
| Muitinės tarifo numeris | 85366990 |
| (Aplinkos sąlygos) | 16 mm (40 mm²) |
| Kontaktinė medžiaga (bendroji) | Copper alloy |
| Nominali srovė (matmenys) | 200 A |
| Plotis (pagrindiniai komerciniai duomenys) | 34.2 mm |
| (Standartai ir reglamentai) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Aukštis (pagrindiniai komerciniai duomenys) | 54.5 mm |
| Ilgis (pagrindiniai komerciniai duomenys) | 29.4 mm |
| Jungties profilis (matmenys) | 1 |
| Nominali viršįtampio įtampa (matmenys) | 8 kV |
| Kontaktinio nešiklio medžiaga (bendroji) | PC |
| Kontaktinio paviršiaus medžiaga (bendroji) | Ag |
| Nominali įtampa (III/3) (Matmenys) | 1000 V |
| Serija (mechaninės charakteristikos) | HC-M-HS |
| Vieneto svoris (be pakuotės) | 71.600 g |
| Šešiakampis lizdas (aplinkos sąlygos) | WAF 5 |
| Kinijos RoHS (standartai ir reglamentai) | Environmentally Friendly Use Period = 50 |
| Priveržimo sukimo momentas (aplinkos sąlygos) | 8 Nm (25 mm² ... 35 mm²) |
| Jungtis (mechaninės charakteristikos) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go in the contact chamber (until the insulation touches the contact). Hold wires in position and use socket wrench to tighten. The used wire end should be cut off before connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Minimalus korpuso aukštis (aplinkos sąlygos) | 72 mm |
| Laidininko skerspjūvis (aplinkos sąlygos) | 25 mm² ... 40 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Prijungimo būdas (mechaninės charakteristikos) | Axial screw connection |
| Prijungimas pagal standartą (medžiagos duomenys) | UL |
| Taršos laipsnis (mechaninės charakteristikos) | 3 |
| Įdėjimo / ištraukimo ciklai (aplinkos sąlygos) | ≥ 500 |
| Jungties skerspjūvis AWG (aplinkos sąlygos) | 3 ... 2 |
| Viršįtampio kategorija (mechaninės charakteristikos) | III |
| Surinkimo instrukcijos (mechaninės charakteristikos) | - Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only be operated without load/voltage. |
| Modulių lizdų skaičius (mechaninės charakteristikos) | 2 |
| Degumo įvertinimas pagal UL 94 (medžiagos duomenys) | V0 |
| Laido skersmuo su izoliacija (aplinkos sąlygos) | 12 mm (25 mm²) |
| Aplinkos temperatūra (darbinė) (elektrinės charakteristikos) | -40 °C ... 125 °C |
| Atskiro laido izoliacijos ilgis (aplinkos sąlygos) | 16 mm |
| Degumo įvertinimas pagal UL 94 (mechaninės charakteristikos) | V0 |