| Parametras | Vertė |
|---|---|
| Prekė | Specifications |
| PFHD | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| Svoris | Net weight: 250 g approx. |
| Išsami informacija | Applicantion expansion unit for the SF4B series |
| Produktas | Exclusive Control Unit for Safety Light Curtain |
| Medžiaga | Enclosure: ABS |
| Dalies numeris | SF-C14EX |
| Produkto pavadinimas | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Maitinimo įtampa | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Produkto numeris | SF-C14EX |
| Aplinkos drėgmė | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Kontrolės kategorija | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Atsparumas smūgiams | 30 G acceleration in X, Y and Z directions three times each |
| Nutildymo lempos išvestis | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Aplinkos temperatūra | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| Prijungimo terminalas | Detachable spring-cage terminal |
| Srovės suvartojimas | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Atsparumas vibracijai | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| Izoliacijos varža | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Taikomi standartai: Japonija | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Atitiktis CE ženklinimo direktyvai | Machinery Directive, EMC Directive, RoHS Directive |
| Taikomi standartai: Europa (ES) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Prijungiamos apsauginės šviesos užuolaidos | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| Taikomi standartai: Šiaurės Amerika | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Išjungimo lempos išvestis: apsaugos grandinė | Incorporated |
| Taikomi standartai: tarptautinis standartas | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| Atsparumas aplinkos poveikiui: apsaugos laipsnis | Enclosure: IP40Terminal: IP20 |
| Atsparumas aplinkai: dielektrinė įtampa | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Saugos išėjimai (1 saugos išėjimas, 2 saugos išėjimas, 3 saugos išėjimas) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| Saugos išėjimai (1 saugos išėjimas, 2 saugos išėjimas, 3 saugos išėjimas): Reakcijos laikas | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| Pagalbiniai išėjimai (1 pagalbinis išėjimas, 2 pagalbinis išėjimas, 3 pagalbinis išėjimas, 4 pagalbinis išėjimas) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| Saugos išėjimai (1 saugos išėjimas, 2 saugos išėjimas, 3 saugos išėjimas): veikimo režimas (išėjimo veikimas) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| Saugos išėjimai (1 saugos išėjimas, 2 saugos išėjimas, 3 saugos išėjimas): apsaugos grandinė (apsauga nuo trumpojo jungimo) | Incorporated |
| Pagalbiniai išėjimai (1 pagalbinis išėjimas, 2 pagalbinis išėjimas, 3 pagalbinis išėjimas, 4 pagalbinis išėjimas): veikimo režimas (išėjimo veikimas) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| Pagalbiniai išėjimai (1 pagalbinis išėjimas, 2 pagalbinis išėjimas, 3 pagalbinis išėjimas, 4 pagalbinis išėjimas): apsaugos grandinė (apsauga nuo trumpojo jungimo) | Incorporated |