| Parametras | Vertė |
|---|---|
| Prekė | Specifications |
| Pastaba | (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
| Svoris | Net weight: 30 g approx., Gross weight: 125 g approx. |
| Išsami informacija | Discrete wire type |
| Ekranas | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Produktas | Dual Display Digital Pressure Sensor [For Gas] |
| Medžiaga | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
| Apsauga | IP40(IEC) |
| Priedai | CN-14A-C2 (Connector attached cable 2 m6.562 ft): 1 pc. |
| Dalies numeris | DP-101ZL3-M-P |
| Kabelio ilgis | Total length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable. |
| Produkto pavadinimas | Dual Display Digital Pressure Sensor [For Gas] DP-100L |
| Slėgio jungtis | M5 female thread |
| Produkto numeris | DP-101ZL3-M-P |
| Maitinimo įtampa | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Aplinkos drėgmė | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Taikomas skystis | Non-corrosive gas |
| Rezultatų rodiklis | Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON) |
| Atsparumas smūgiams | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Slėgio tipas | Gauge pressure |
| Prijungimo būdas | Connector |
| Energijos suvartojimas | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
| Nustatykite slėgio diapazoną | -101.0 to +101.0kPa |
| Aplinkos temperatūra | -10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉ |
| Valdymo išėjimas (DO) | PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current) |
| Nominalus slėgio diapazonas | -100.0 to +100.0 kPa |
| Atsparumas vibracijai | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Izoliacijos varža | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
| Įtampos atsparumas | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Atsparumas slėgiui | 500kPa |
| Temperatūros charakteristikos | Within ±0.5 % F.S.(at +20℃+68℉) |
| Valdymo išėjimas (DO): histerezė | Minimum 1 digit (variable) |
| Valdymo išvestis (DO): Pakartojamumas | ±0.1 % F.S. (within ±2 digits) |
| Valdymo išvestis (DO): Reakcijos laikas | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Ekranas: rodomas slėgio diapazonas | -101.0 to +101.0 kPa |
| Ryšio išvestis (C/Q): baudos sparta | COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Valdymo išėjimas (DO): išėjimo veikimas | N.O./N.C. (selectable by key operation) |
| Ryšio išvestis (C/Q): proceso duomenys | 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Atitiktis reglamentams ir sertifikavimas | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification |
| Valdymo išėjimas (DO): Apsauga nuo trumpojo jungimo | Incorporated |
| Ryšio išvestis (C/Q): Minimalus ciklo laikas | 1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Ryšio išvestis (C/Q): IO-Link ryšys | IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Valdymo išvestis (DO): Išvesties veikimas, Išvesties režimai | EASY mode / Hysteresis mode / Window comparator mode |
Techninės specifikacijos ir našumo duomenys
Montavimo ir naudojimo vadovas