| Parametras | Vertė |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| Ie | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Prekė | Specifications |
| Kabelis | UL style 2464, No.22 AWG 12-core |
| Svoris | Approx. 680 g |
| Produktas | Safety door switch with key |
| Medžiaga | Enclosure : PA66 |
| Apsauga | IP 65 (IEC 60529) |
| Dalies numeris | SG-B2-K2AC-5 |
| Kabelio ilgis | 5m16.404 ft |
| Produkto pavadinimas | Safety door switch with key SG-B2 |
| Produkto numeris | SG-B2-K2AC-5 |
| Blokavimo jėga | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Atsparumas smūgiams | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Kontaktinis pasipriešinimas | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Kontaktų tvarka | |
| Veikimo dažnis | 900 operations/hour |
| Taikomi standartai | EN 60947-5-1, GS-ET-19 |
| Tiesioginė atidarymo jėga | 80 N min. |
| Rakto ištraukimo padėtis | A(removable in all positions) |
| Atsparumas vibracijai | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Tiesioginio atidarymo eiga | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| Elektrinis patvarumas | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| Mechaninis patvarumas | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| Šiluminė srovė (Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| Taikomi reglamentai | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Indukcinė apkrova (AC-15) | - |
| Indukcinė apkrova (DC-13) | 2.3A |
| Pavaros veikimo greitis | 0.05 to 1.0 m/sec. |
| Žymėjimas: Tiesioginio atidarymo jėga | 0.6 N・m min. |
| Raktas: pagrindinis tempiamasis stipris | 1.0 N・m min. |
| Žymėjimas: Tiesioginio atidarymo laipsnis | 60°min. |
| Raktas: Mechaninis patvarumas | 100,000 operations min. |
| Nominali izoliacijos įtampa (Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| Raktas: pagrindinis eksploatacinis patvarumas | 10,000 operations min. |
| Raktas: Veikimo specifikacijos | 2 positions |
| Darbinė būklė: Aukštis | 2,000 m6,561.68 ftmax. |
| Elektros smūgio apsaugos klasė | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Apsaugos nuo trumpojo jungimo įtaisas | Use 250 V / 10 A fast acting type fuse |
| Impulsinė atlaikymo įtampa (Uimp) | 2.5 kV |
| Sąlyginė trumpojo jungimo srovė | 50 A (250 V) |
| Darbinė būklė: aplinkos drėgmė | 45 to 85 % RH |
| Darbinės sąlygos: Taršos laipsnis | 3 (Inside 2) |
| Taikomi standartai: Naudojimo standartai | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Darbinė temperatūra: aplinkos temperatūra | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Nominali darbinė įtampa (Ue) / Nominali darbinė srovė (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Techninės specifikacijos ir našumo duomenys
Montavimo ir naudojimo vadovas